The Jandy Apure35 is a high-performance salt chlorine generator designed for residential swimming pools up to 35,000 gallons. This system automatically converts salt into chlorine to keep your pool clean and sanitized. Features include digital controls, self-cleaning cell, built-in safety features, and compatibility with various pool systems. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting to Pool System 7. Operation and Maintenance 8. Safety Features 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Control panel, Salt cell, Flow sensor, Power supply unit, Temperature sensor.

FeatureDescription
Control panelDigital display with push-button controls
Salt cellSelf-cleaning titanium electrodes
Flow sensorMonitors water flow for safety
Power supply120V/240V compatible transformer
Temperature sensorMonitors water temperature
Chlorine outputAdjustable from 20% to 100%
Super chlorinate24-hour boost mode
Cell cleaningAutomatic reverse polarity
Error indicatorsLED status lights for diagnostics
Waterproof housingNEMA 4X rated enclosure

Installation

Unpack and inspect contents. Ensure proper location near pool equipment.

  1. Mount control unit: Install on wall near pool equipment pad using provided brackets.
  2. Install salt cell: Connect to pool plumbing after filter and before heater.
  3. Electrical connection: Connect to dedicated GFCI circuit breaker.
  4. Flow sensor installation: Install in plumbing line before salt cell.
  5. Final connections: Verify all plumbing and electrical connections are secure.

WARNING! Installation must be performed by qualified professional. Ensure power is disconnected during installation.

First-Time Setup

Power on system; follow initial setup procedure.

  1. Add salt: Add pool salt to achieve 3000-3500 ppm concentration.
  2. Prime system: Run pump for 24 hours to dissolve salt completely.
  3. Set chlorine output: Adjust percentage based on pool size and usage.
  4. Calibrate sensors: Allow system to auto-calibrate during first 48 hours.
  5. Test water: Verify proper salt levels and chlorine production.

CAUTION! Do not operate without proper water flow. Ensure salt is fully dissolved before activating cell.

Specifications

Controls and Settings

Access controls via front panel digital display and push buttons.

Control Panel: POWER, MENU, UP/DOWN arrows, ENTER, SUPER CHLORINATE, CELL CLEANING.

Settings: Chlorine output (20-100%), Pool type selection, Temperature display, Salt level display, Error codes, System status, Runtime hours, Cell cleaning cycle, Super chlorinate timer, Factory reset.

Connecting to Pool System

Integration with existing pool equipment and automation systems.

  1. Pump connection: Requires compatible variable speed pump.
  2. Heater integration: Connect to gas or heat pump heater.
  3. Automation systems: Compatible with Jandy Aqualink and other systems.
  4. Water features: Ensure proper flow for waterfalls and fountains.

Tip: Consult professional installer for complex system integrations.

Operation and Maintenance

Daily operation and routine maintenance procedures.

  1. Daily: Check salt levels and chlorine production.
  2. Weekly: Test water chemistry and clean cell if needed.
  3. Monthly: Inspect cell for scale buildup.
  4. Seasonal: Winterize system in freezing climates.
  5. Annual: Professional inspection and calibration.

WARNING! Always turn off power before performing maintenance. Wear protective equipment when handling chemicals.

Safety Features

Built-in safety mechanisms for reliable operation.

Care & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Cell cleaning: Use diluted muriatic acid solution for scale removal
  2. Control unit: Wipe with damp cloth only
  3. Plumbing connections: Check for leaks regularly
  4. Electrical connections: Ensure tight and corrosion-free

CAUTION! Use only approved cleaning solutions. Never use abrasive cleaners on control panel.

Regulatory Information

UL listed and certified to NSF/ANSI 50 standards. Complies with local electrical codes. Copyright © 2024 Jandy Products. All rights reserved. For technical support, visit www.jandy.com or contact 1-800-227-1442.

Troubleshooting

SymptomPossible CauseCorrective Action
No chlorine productionLow salt/Low flowCheck salt levels; verify pump operation; clean cell
High salt warningExcessive saltDilute pool water; test salt concentration
Low salt warningInsufficient saltAdd pool salt; allow 24 hours to dissolve
Flow errorPump not runningCheck pump operation; clean filter; verify flow switch
Cell cleaning requiredScale buildupPerform manual cell cleaning; check water balance
Temperature errorExtreme water tempWait for temperature to normalize; check sensor

Reset: Press and hold MENU + POWER for 10 seconds.

Service: 1-800-227-1442; www.jandy.com