Jandy AquaLink RS PureLink Manual

The Jandy AquaLink RS PureLink is an advanced pool and spa control system featuring wireless remote control capability, integrated automation for pool equipment, compatibility with various pool systems, touchscreen interface, smartphone connectivity, energy management features, and comprehensive system diagnostics. Designed for residential pool and spa applications with 120V/240V compatibility. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Devices 7. System Operation 8. Automation Features 9. Maintenance & Care 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Main control unit, Wireless remote, Touchscreen interface, Power center, Valve actuators, Sensor inputs.

FeatureDescription
Wireless ControlRemote operation of pool/spa functions
Touchscreen InterfaceIntuitive control panel with LCD display
Smartphone ConnectivityMobile app control and monitoring
Energy ManagementProgrammable schedules for energy efficiency
Valve ControlAutomated valve positioning
Temperature ControlPrecise pool and spa temperature management
System DiagnosticsReal-time monitoring and fault detection
Pump ControlVariable speed pump integration
Lighting ControlPool and spa lighting automation
Safety FeaturesChild lock and safety timeout

Installation

Unpack and inspect contents. Mount control unit in protected location.

  1. Mount control unit: Choose dry, protected location near equipment pad.
  2. Connect power: Follow local electrical codes; use proper grounding.
  3. Connect pool equipment: Pump, heater, lights, valves to appropriate terminals.
  4. Install wireless antenna: Mount in clear location for optimal signal.
  5. Connect sensors: Temperature and pressure sensors as required.

WARNING! Installation must be performed by qualified technician. Disconnect power before installation.

First-Time Setup

Power on system; follow on-screen initialization.

  1. System initialization: Power on; system will run self-test and initialization.
  2. Configure basic settings: Set time, date, and location parameters.
  3. Program equipment: Assign functions to relays and configure pump settings.
  4. Set temperature limits: Configure pool and spa temperature ranges.
  5. Connect mobile app: Download Jandy app and pair with system.

CAUTION! Ensure all electrical connections are secure and properly rated.

Specifications

Controls and Settings

Access menu via touchscreen or remote. Main controls: POWER, MENU, SELECT, BACK, FUNCTION keys.

Remote: POWER, MENU, POOL/SPA, LIGHTS, TEMP UP/DOWN, FILTER, CLEAN, AUX buttons.

System Settings: Time/Date, Language, Temperature units, Backlight, Sound. Equipment Settings: Pump speeds, Heater settings, Light modes, Valve positions. Automation: Schedules, Timers, Macros, Scenes. Security: User codes, Child lock, Service mode.

Connecting Devices

Equipment connections: Pump, Heater, Lights, Valves. Auxiliary devices: Water features, Cleaners, Sensors.

  1. Turn off main power before connecting devices.
  2. Connect pump: Variable speed pump to comm port.
  3. Connect heater: Low voltage fireman's switch.
  4. Connect lights: Low voltage transformer control.
  5. Connect valves: Valve actuator wiring.

Tip: Label all wires during installation for easy identification.

System Operation

Daily operation of pool and spa functions.

  1. Power on: Press POWER button on control panel or remote.
  2. Select mode: Choose POOL or SPA mode as needed.
  3. Adjust temperature: Use TEMP buttons to set desired temperature.
  4. Control equipment: Press corresponding function buttons for pump, lights, etc.
  5. Set timers: Program filter cycles and equipment run times.
  6. Monitor status: Check system status on display.
  7. Shutdown: Press POWER to enter standby mode.

WARNING! Never operate system with cover removed. Keep children away from equipment.

Automation Features

Programmable schedules for energy efficiency and convenience.

Maintenance & Care

Regular maintenance ensures optimal performance and longevity.

  1. Monthly inspection: Check connections and enclosure integrity
  2. Display cleaning: Use soft, dry cloth only
  3. Battery replacement: Replace remote batteries annually
  4. Software updates: Check for firmware updates periodically
  5. Winterization: Proper shutdown for cold climates

CAUTION! Disconnect power before performing any maintenance. Use only qualified service technicians.

Regulatory Information

UL 1563 Listed: Swimming pool equipment. FCC Part 15: Class B digital device compliance. CSA C22.2 No. 218.1: Swimming pool equipment standard. Copyright © 2024 Jandy. All rights reserved. Jandy and AquaLink are registered trademarks of Fluidra. For technical support, visit www.jandy.com or contact 1-800-227-1442.

Troubleshooting

SymptomPossible CauseCorrective Action
No power to systemPower supply issueCheck circuit breaker; verify power at terminals
Wireless remote not workingBatteries/rangeReplace batteries; move closer to control unit
Pump not respondingCommunication errorCheck comm wiring; reset pump communication
Temperature reading incorrectSensor issueCheck sensor wiring; replace if faulty
Display blankPower/backlightCheck power supply; adjust backlight settings
Heater not firingSafety lockoutCheck error codes; reset heater
Valves not movingActuator powerCheck actuator wiring and power supply

Reset: Menu > System > Reset to factory defaults if needed.

Service: 1-800-227-1442; www.jandy.com

Jandy AquaLink RS PureLink Manual © - All Rights Reserved 2025