jandy aqualink rs6 manual pdf

The Jandy Aqualink RS6 is a sophisticated pool and spa control system that allows centralized management of pool equipment including pumps, heaters, lights, and water features. This system features a user-friendly interface, remote control capabilities, and advanced automation for optimal pool maintenance and energy efficiency. Below are key sections covering system overview, installation, programming, operation, troubleshooting, and maintenance.

1. System Overview 2. Installation Requirements 3. Initial Setup 4. Technical Specifications 5. Control Panel Operation 6. Equipment Connections 7. Programming Functions 8. Remote Access Features 9. Maintenance Guidelines 10. Compliance Information 11. Troubleshooting Guide

System Overview

Key components: Main control unit, user interface panel, remote transmitters, valve actuators, and sensor inputs.

ComponentDescription
Main Control UnitCentral processing unit for all pool/spa equipment
User Interface PanelTouchpad control with LCD display
Remote TransmittersWireless remote control units
Valve ActuatorsAutomated control of pool/spa valves
Sensor InputsTemperature, pressure, and flow sensors
Pump ControlVariable speed pump management
Heater ControlPool/spa temperature regulation
Light ControlPool and spa lighting management
Auxiliary ControlsWater features, cleaners, and additional equipment
Power Supply24V AC transformer

Installation Requirements

Proper installation requires electrical knowledge and compliance with local codes.

  1. Mount control unit: Install in dry, ventilated area away from direct water exposure.
  2. Electrical connections: Connect to dedicated 240V circuit with proper grounding.
  3. Equipment wiring: Route low-voltage cables to pumps, heaters, and valves.
  4. Sensor installation: Place temperature sensors in appropriate locations.
  5. Valve actuator setup: Install on pool/spa valves for automated control.

WARNING! Installation must be performed by qualified technician. Risk of electrical shock if improperly installed.

Initial Setup

Power on system and configure basic settings.

  1. System initialization: Power up control unit and allow self-test to complete.
  2. Time/date setup: Configure system clock for proper scheduling.
  3. Equipment identification: Assign functions to auxiliary circuits.
  4. Temperature settings: Set desired pool and spa temperatures.
  5. Program schedules: Establish pump run times and filter cycles.

CAUTION! Ensure all equipment is properly wired before powering system.

Technical Specifications

Control Panel Operation

Access system functions through main control panel or remote units.

Main Controls: POOL/SPA mode, FILTER, HEATER, LIGHTS, CLEANER, AUX buttons.

Menu Navigation: Use arrow keys to navigate menus, SELECT to choose options, MENU to access main menu. Settings: Temperature control, schedule programming, system configuration, diagnostic mode. Display: Shows current status, temperatures, equipment status, and error messages.

Equipment Connections

Connect pool and spa equipment to appropriate terminals.

  1. Pump connections: Wire pump to dedicated relay or communication bus.
  2. Heater control: Connect to fireman's switch or direct control terminals.
  3. Light circuits: Connect pool and spa lights to auxiliary relays.
  4. Valve actuators: Wire to valve control terminals with proper polarity.
  5. Sensors: Connect temperature and pressure sensors to designated inputs.

Tip: Label all wires during installation for easy identification during maintenance.

Programming Functions

Advanced programming for automated pool management.

  1. Schedule programming: Set daily/weekly pump and filter schedules.
  2. Temperature settings: Program different temperatures for pool and spa modes.
  3. Cleaner cycles: Schedule automatic pool cleaner operation.
  4. Light shows: Program lighting sequences and color changes.
  5. Valve programming: Set automatic valve positions for different modes.
  6. Freeze protection: Configure automatic pump operation during freezing conditions.
  7. Energy savings: Program pump speeds for optimal energy efficiency.
  8. Remote access: Set up wireless control and smartphone integration.

WARNING! Save all programming changes before exiting menu. Unsaved changes will be lost.

Remote Access Features

Wireless control options including remote units and smartphone apps.

Wireless Remotes: Battery-powered handheld units with full system control. Smartphone App: Aqualink Connect for iOS and Android devices. Web Interface: Remote access via internet connection. Features: Real-time status monitoring, temperature adjustments, equipment control, scheduling changes.

Maintenance Guidelines

Regular maintenance ensures optimal system performance.

  1. Monthly checks: Inspect wiring connections and enclosure integrity.
  2. Seasonal maintenance: Check sensors and valve actuators for proper operation.
  3. Battery replacement: Replace remote control batteries annually.
  4. Software updates: Check for firmware updates periodically.
  5. Display cleaning: Clean touchpad with soft, dry cloth only.

CAUTION! Disconnect power before performing any maintenance on electrical components.

Compliance Information

UL listed and complies with NEC Article 680 for swimming pool equipment. FCC Part 15: Class B digital device compliant. Manufactured by Jandy Pool Products, a division of Fluidra. For technical support, visit www.jandy.com or contact 1-800-227-1442.

Troubleshooting Guide

SymptomPossible CauseCorrective Action
No display on control panelPower loss or transformer issueCheck circuit breaker; verify transformer output; inspect wiring.
Pump not respondingCommunication error or power issueCheck pump power; verify communication cable; reset system.
Heater not heatingTemperature sensor or control issueVerify sensor readings; check heater power; inspect fireman's switch.
Remote not workingBattery or signal interferenceReplace batteries; check distance; ensure clear line of sight.
Valves not movingActuator power or mechanical issueCheck actuator voltage; inspect for mechanical binding; verify programming.
Communication errorsWiring issues or device failureCheck RS-485 wiring; verify termination resistors; reset communication bus.

Reset Procedure: Menu > System > Reset to factory defaults if needed.

Technical Support: 1-800-227-1442; www.jandy.com