The Jandy LRZ is a high-performance pool and spa control system featuring advanced automation capabilities, remote control access, water temperature management, pump control, lighting control, and safety features. Designed for residential and commercial pool applications with easy installation and user-friendly interface. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Devices 7. Operating Modes 8. Safety Features 9. Maintenance & Care 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Main control unit, Remote control panel, Temperature sensors, Pump relay outputs, Valve actuators, Power supply unit.

FeatureDescription
Main control unitCentral processing and relay control for all pool systems
Remote control panelWall-mounted interface for system operation
Temperature sensorsWater and air temperature monitoring
Pump relay outputsControls pool pump operation and speed settings
Valve actuatorsAutomated control of pool water flow direction
Power supply unit24V AC transformer for system power
Lighting controlPool and spa lighting operation
Heater controlPool and spa water temperature regulation
Timer functionsProgrammable operation schedules
Safety shutdownAutomatic system protection features

Installation

Unpack and inspect contents. Install in dry, protected location.

  1. Mount control unit: Choose indoor location away from moisture and direct sunlight.
  2. Connect power supply: Use dedicated 120V AC circuit with proper grounding.
  3. Connect pump and heater: Follow wiring diagram for proper relay connections.
  4. Install temperature sensors: Place in appropriate locations for accurate readings.
  5. Connect valve actuators: Ensure proper alignment and wiring.

WARNING! Electrical installation must be performed by qualified technician. Ensure all connections are secure and properly grounded.

First-Time Setup

Power on system; follow initial configuration prompts.

  1. Set date and time: Use menu system to configure current date and time.
  2. Configure pump settings: Set pump type, speed settings, and run times.
  3. Set temperature limits: Configure desired pool and spa temperature ranges.
  4. Program lighting: Set pool and spa light operation schedules.
  5. Test all functions: Verify proper operation of all connected equipment.

CAUTION! Ensure proper water chemistry before operating pool equipment.

Specifications

Controls and Settings

Access system menu via control panel buttons. Front Panel: MENU, SELECT, UP/DOWN arrows, ENTER, BACK.

Remote Control: POWER, MODE, TEMP UP/DOWN, LIGHT, PUMP, MENU, SELECT, ENTER.

System Settings: Date/Time, Temperature units (°F/°C), Language selection. Pump Control: Speed settings, Run times, Schedule programming. Heater Control: Set point temperature, Heater type configuration. Lighting: On/Off control, Color settings, Schedule programming. Valve Control: Position settings, Program sequences.

Connecting Devices

Pump connections: Relay outputs 1-4. Heater connections: Relay output 5. Lighting: Relay outputs 6-7. Auxiliary: Relay output 8.

  1. Turn off main power before making connections.
  2. Follow wiring diagram for proper terminal connections.
  3. Use appropriate gauge wire for all connections.
  4. Test each connection before final installation.

Tip: Label all wires for easy identification during maintenance.

Operating Modes

Supports automatic, manual, and service modes.

  1. Automatic Mode: Follows programmed schedule for all functions.
  2. Manual Mode: Override automatic operation for immediate control.
  3. Service Mode: Disables automatic functions for maintenance.
  4. Freeze Protection: Automatic pump operation during freezing conditions.
  5. Vacation Mode: Reduced operation for energy savings.
  6. Quick Clean: Enhanced filtration for water cleaning.

WARNING! Do not operate pool without proper water level and filtration.

Safety Features

Freeze Protection: Automatic pump operation below 34°F. High Limit Protection: Prevents overheating. Low Water Protection: Shuts off pump if water level is low. Child Safety Lock: Prevents unauthorized operation.

Maintenance & Care

Regular maintenance ensures optimal performance and longevity.

  1. Monthly: Check all connections and clean control panel.
  2. Quarterly: Verify temperature sensor accuracy.
  3. Annually: Professional inspection of all electrical components.
  4. As needed: Update firmware for latest features.

CAUTION! Disconnect power before performing any maintenance.

Regulatory Information

UL Listed: Meets UL 1563 standards for pool and spa equipment. FCC Part 15: Class A digital device compliance. CSA Certified: Canadian Standards Association approval. Copyright © 2024 Jandy Products; all rights reserved. For technical support, visit www.jandy.com or contact 1-800-227-1442.

Troubleshooting

SymptomPossible CauseCorrective Action
No display on control panelPower loss or transformer issueCheck power supply and circuit breaker; verify transformer output.
Pump not runningRelay failure or wiring issueCheck relay operation; verify pump wiring connections.
Inaccurate temperature readingSensor failure or placementReplace temperature sensor; ensure proper sensor location.
Heater not activatingCommunication error or limit switchCheck heater communication cable; verify high limit switch.
System not following scheduleClock error or programmingReset date/time; reprogram schedule settings.

Reset: Menu > System > Factory Reset if available.

Service: 1-800-227-1442; www.jandy.com