Jandy LT Heater Manual

The Jandy LT Heater is a high-efficiency pool and spa heater designed for reliable performance and easy operation. This gas-fired heater features electronic ignition, digital temperature control, corrosion-resistant components, safety shut-off systems, and compatibility with various pool automation systems. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation Requirements 3. First-Time Setup 4. Technical Specifications 5. Controls and Operation 6. Connecting to Pool Systems 7. Maintenance Procedures 8. Safety Features 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital control panel, Heat exchanger, Burner assembly, Gas valve, Water pressure switch, Thermal regulator, Exhaust system.

FeatureDescription
Digital control panelLCD display with temperature settings and status indicators
Electronic ignitionReliable spark ignition system for consistent starts
Heat exchangerCupro-nickel construction for corrosion resistance
Gas valvePrecise gas flow control with safety shut-off
Water pressure switchEnsures proper water flow before ignition
Thermal regulatorMaintains optimal operating temperature
Exhaust systemVented combustion chamber for safe operation
POWER buttonTurns heater on/off
TEMP controlsUp/down buttons for temperature adjustment
POOL/SPA modeSwitches between pool and spa heating modes

Installation Requirements

Unpack and inspect all components. Ensure proper location and clearances.

  1. Location: Install on level, stable surface with adequate ventilation and clearance from combustible materials.
  2. Gas connection: Use approved gas piping; check for leaks with soap solution.
  3. Water connections: Connect to pool plumbing with proper unions and valves.
  4. Electrical: Connect to proper power source with GFCI protection.
  5. Venting: Ensure proper exhaust venting according to local codes.

WARNING! Installation must be performed by qualified technician. Gas leaks can cause explosion or fire.

First-Time Setup

Power on heater; follow startup sequence.

  1. Check water flow: Ensure pool pump is running and water is circulating.
  2. Gas supply: Verify gas valve is open and supply is adequate.
  3. Set temperature: Use TEMP buttons to set desired pool/spa temperature.
  4. Select mode: Choose POOL or SPA mode based on application.
  5. Start heating: Press POWER to begin heating cycle.

CAUTION! Do not operate without proper water flow. Ensure all safety systems are functional.

Technical Specifications

Controls and Operation

Access controls via digital panel. Front Panel: POWER, TEMP UP/DOWN, POOL/SPA, MENU.

Remote Control: Available for compatible models with temperature adjustment and mode selection.

Temperature Settings: Range from 65°F to 104°F. Mode Selection: POOL for general heating, SPA for rapid heating. Menu Options: System diagnostics, error codes, service mode. Safety: Automatic shut-off for high temperature, low water flow, or gas supply issues.

Connecting to Pool Systems

Compatible with Jandy automation systems and most pool controllers.

  1. Turn off power to heater and automation system.
  2. Connect communication cable to automation interface.
  3. Connect water temperature sensor if required.
  4. Configure automation system for heater control.
  5. Test remote operation through automation interface.

Tip: Ensure proper communication protocol settings for compatibility with your automation system.

Maintenance Procedures

Regular maintenance ensures optimal performance and longevity.

  1. Monthly: Check for debris around unit and clean filter.
  2. Quarterly: Inspect burner assembly and heat exchanger.
  3. Annually: Professional inspection of gas connections, electrical components, and safety systems.
  4. Seasonal: Winterize if located in freezing climates.
  5. Water Chemistry: Maintain proper pool chemistry to prevent scale and corrosion.

WARNING! Always turn off gas and electrical power before performing maintenance.

Safety Features

Multiple safety systems protect against hazardous conditions.

Safety FeatureFunction
Water Pressure SwitchPrevents operation without adequate water flow
High Limit SwitchShuts off heater if temperature exceeds safe limits
Flame Rollout SwitchDetects improper burner operation
Gas Valve SafetyAutomatic shut-off for gas supply issues
Thermal FuseProtects against overheating

Care & Cleaning

Turn off power before cleaning. Keep area around heater clear of debris.

  1. Exterior: Wipe with damp cloth; do not use harsh chemicals.
  2. Vents: Keep exhaust and intake vents clear of obstructions.
  3. Burner compartment: Have professional clean annually.
  4. Heat exchanger: Professional inspection for scale buildup.

CAUTION! Do not spray water directly on electrical components. Keep flammable materials away from heater.

Regulatory Information

UL listed and certified to ANSI Z21.56 standards. Complies with CSA requirements for pool heaters. Manufactured to meet EPA emissions standards where applicable. Copyright © Jandy Products. All specifications subject to change without notice. For technical support, contact Jandy Technical Support at 1-800-227-1442 or visit www.jandy.com.

Troubleshooting

SymptomPossible CauseCorrective Action
Heater won't startPower supply/water flowCheck circuit breaker; ensure pump is running; verify water flow.
No ignitionGas supply/ignition systemCheck gas valve; verify spark ignition; inspect electrode.
Error codes displayedSystem faultsRefer to error code chart in manual; reset system if safe.
Insufficient heatingGas pressure/flow rateCheck gas pressure; verify proper water flow; clean filter.
Frequent shutdownsSafety system activationCheck water flow switch; inspect high limit switch; verify venting.

Reset: Turn power off for 30 seconds, then restart.

Service: 1-800-227-1442; www.jandy.com