The Jandy LT Heater is a high-efficiency pool and spa heater designed for reliable performance and easy operation. This gas-fired heater features electronic ignition, digital temperature control, corrosion-resistant components, safety shut-off systems, and compatibility with various pool automation systems. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Digital control panel, Heat exchanger, Burner assembly, Gas valve, Water pressure switch, Thermal regulator, Exhaust system.
| Feature | Description |
|---|---|
| Digital control panel | LCD display with temperature settings and status indicators |
| Electronic ignition | Reliable spark ignition system for consistent starts |
| Heat exchanger | Cupro-nickel construction for corrosion resistance |
| Gas valve | Precise gas flow control with safety shut-off |
| Water pressure switch | Ensures proper water flow before ignition |
| Thermal regulator | Maintains optimal operating temperature |
| Exhaust system | Vented combustion chamber for safe operation |
| POWER button | Turns heater on/off |
| TEMP controls | Up/down buttons for temperature adjustment |
| POOL/SPA mode | Switches between pool and spa heating modes |
Unpack and inspect all components. Ensure proper location and clearances.
WARNING! Installation must be performed by qualified technician. Gas leaks can cause explosion or fire.
Power on heater; follow startup sequence.
CAUTION! Do not operate without proper water flow. Ensure all safety systems are functional.
Access controls via digital panel. Front Panel: POWER, TEMP UP/DOWN, POOL/SPA, MENU.
Remote Control: Available for compatible models with temperature adjustment and mode selection.
Temperature Settings: Range from 65°F to 104°F. Mode Selection: POOL for general heating, SPA for rapid heating. Menu Options: System diagnostics, error codes, service mode. Safety: Automatic shut-off for high temperature, low water flow, or gas supply issues.
Compatible with Jandy automation systems and most pool controllers.
Tip: Ensure proper communication protocol settings for compatibility with your automation system.
Regular maintenance ensures optimal performance and longevity.
WARNING! Always turn off gas and electrical power before performing maintenance.
Multiple safety systems protect against hazardous conditions.
| Safety Feature | Function |
|---|---|
| Water Pressure Switch | Prevents operation without adequate water flow |
| High Limit Switch | Shuts off heater if temperature exceeds safe limits |
| Flame Rollout Switch | Detects improper burner operation |
| Gas Valve Safety | Automatic shut-off for gas supply issues |
| Thermal Fuse | Protects against overheating |
Turn off power before cleaning. Keep area around heater clear of debris.
CAUTION! Do not spray water directly on electrical components. Keep flammable materials away from heater.
UL listed and certified to ANSI Z21.56 standards. Complies with CSA requirements for pool heaters. Manufactured to meet EPA emissions standards where applicable. Copyright © Jandy Products. All specifications subject to change without notice. For technical support, contact Jandy Technical Support at 1-800-227-1442 or visit www.jandy.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Heater won't start | Power supply/water flow | Check circuit breaker; ensure pump is running; verify water flow. |
| No ignition | Gas supply/ignition system | Check gas valve; verify spark ignition; inspect electrode. |
| Error codes displayed | System faults | Refer to error code chart in manual; reset system if safe. |
| Insufficient heating | Gas pressure/flow rate | Check gas pressure; verify proper water flow; clean filter. |
| Frequent shutdowns | Safety system activation | Check water flow switch; inspect high limit switch; verify venting. |
Reset: Turn power off for 30 seconds, then restart.