Jandy LXi 400 Manual

The Jandy LXi 400 is a high-efficiency pool heater with advanced digital controls, designed for residential swimming pool applications. This heater features electronic ignition, digital temperature display, easy-to-use control panel, multiple safety systems, and compatibility with various pool sizes. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting to Pool System 7. Operation 8. Maintenance 9. Safety Features 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital control panel, Electronic ignition system, Heat exchanger, Water pressure switch, Temperature sensor, Gas valve assembly.

FeatureDescription
Digital Control PanelLCD display with temperature readout and status indicators
Electronic IgnitionPilotless ignition for reliable startup
Heat ExchangerCopper construction for efficient heat transfer
Water Pressure SwitchEnsures proper water flow before ignition
Temperature SensorMonitors water temperature for precise control
Gas Valve AssemblyRegulates gas flow to burner
Safety LockPrevents unauthorized temperature changes
Freeze ProtectionAutomatic operation in freezing conditions
Error Code DisplayShows diagnostic codes for troubleshooting
Pool/Spa ModeDual temperature settings for pool and spa

Installation

Unpack and inspect contents. Place on level, stable surface near pool equipment.

  1. Gas Connection: Use approved gas piping; check for leaks with soap solution.
  2. Water Connections: Connect to pool return line using appropriate fittings.
  3. Electrical Connection: Connect to 120V AC power source with proper grounding.
  4. Ventilation: Ensure adequate clearance and proper venting as per local codes.

WARNING! Installation must be performed by qualified technician. Follow all local codes and regulations.

First-Time Setup

Power on heater; follow startup procedure.

  1. Initial Power Up: Turn on power; control panel will display startup sequence.
  2. Set Temperature: Use up/down buttons to set desired pool temperature.
  3. Configure Mode: Select POOL or SPA mode based on application.
  4. Test Operation: Verify proper ignition and heating operation.

CAUTION! Ensure proper water flow before starting heater to prevent damage.

Specifications

Controls and Settings

Access settings via digital control panel. Front Panel: POWER, TEMP UP/DOWN, MODE, MENU.

Display Indicators: Temperature readout, Heater status, Error codes, Pool/Spa mode.

Temperature Settings: Adjustable from 50°F to 104°F. Mode Selection: POOL for general heating, SPA for rapid heating. Menu Options: Temperature calibration, Freeze protection settings, Service codes, Factory reset.

Connecting to Pool System

Connect to existing pool plumbing and filtration system.

  1. Turn off pool pump and gas supply before connecting.
  2. Install heater downstream of filter and upstream of chemical feeder.
  3. Use appropriate pipe size and unions for easy service access.
  4. Verify water flow direction matches heater arrows.

Tip: Install isolation valves for easy maintenance and service.

Operation

Supports automatic and manual heating modes.

  1. Startup: Ensure water flow; press POWER button.
  2. Set Temperature: Use TEMP buttons to desired setting.
  3. Monitor: Watch for proper ignition and temperature rise.
  4. Shutdown: Press POWER to turn off; system will cool down.
  5. Pool/Spa Mode: Switch modes as needed for different applications.
  6. Freeze Protection: Automatic operation when temperatures drop below 40°F.
  7. Status Monitoring: Check display for current operating status.
  8. Error Codes: Note any displayed codes for reference.

WARNING! Never operate without proper water flow. Monitor for unusual noises or smells.

Maintenance

Regular maintenance ensures optimal performance and longevity.

  1. Monthly: Check for debris around unit; verify proper water flow.
  2. Seasonal: Inspect burners, heat exchanger, and venting.
  3. Annual: Professional inspection of gas connections and safety devices.
  4. Water Chemistry: Maintain proper pool chemistry to prevent scale buildup.

CAUTION! Turn off power and gas before performing any maintenance.

Safety Features

Multiple safety systems protect against hazardous conditions.

Safety FeatureFunction
Water Pressure SwitchPrevents operation without water flow
High Limit SwitchShuts off heater if temperature exceeds safe limits
Flame Rollout SwitchDetects improper burner operation
Air Flow SwitchEnsures proper venting operation
Gas Valve SafetyAutomatic shutoff if ignition fails

Regulatory Information

UL Listed: Complies with UL Standard 1261. ANSI: Meets ANSI Z21.56 standards. CSA: Certified to CSA 4.7 standards. For Natural Gas and Propane installations. Copyright © Jandy Products. All specifications subject to change without notice. For technical support, visit www.jandy.com or contact 1-800-227-1442.

Troubleshooting

SymptomPossible CauseCorrective Action
Heater won't startNo power/water flowCheck circuit breaker; verify pump is running; check water pressure switch.
No ignitionGas supply/ignitionVerify gas valve open; check for spark at igniter; reset system.
Error code displayedSystem faultRefer to error code chart in manual; note code and contact service.
Poor heatingFlow rate/thermostatCheck filter cleanliness; verify proper water flow; calibrate temperature sensor.
Unusual noisesScale/air in systemCheck for scale buildup; purge air from system; inspect heat exchanger.

Reset: Turn power off for 30 seconds then restart.

Service: 1-800-227-1442; www.jandy.com

Jandy LXi 400 Manual © - All Rights Reserved 2025