Jandy PureLink Manual

The Jandy PureLink is a professional-grade water purification system designed for residential and commercial use. It features advanced filtration technology, multiple purification stages, digital monitoring, automatic backwash cycles, and smart connectivity. The system includes sediment filtration, carbon filtration, reverse osmosis, UV sterilization, and mineral enhancement. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting to Water Supply 7. Operation and Maintenance 8. Smart Features 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Multi-stage filtration system, Digital Control Panel, Smart Connectivity Module, Pressure Gauges, Automatic Backwash Valve, Filter Status Indicators.

FeatureDescription
Sediment FilterRemoves dirt, rust, and particulate matter
Carbon FilterEliminates chlorine, chemicals, and odors
Reverse OsmosisRemoves dissolved solids and contaminants
UV SterilizationKills bacteria and viruses
Mineral EnhancementAdds beneficial minerals to purified water
Digital DisplayShows water quality, filter status, and system alerts
Automatic BackwashSelf-cleaning function for extended filter life
Smart ConnectivityWi-Fi enabled for remote monitoring and control
Pressure GaugesMonitor inlet and outlet water pressure
Filter Status IndicatorsLED lights show filter replacement needs

Installation

Unpack and inspect all components. Choose a dry, level location near water supply and drainage.

  1. Shut off main water supply and drain pipes.
  2. Mount unit on wall using provided brackets and hardware.
  3. Connect inlet pipe to cold water supply line.
  4. Connect outlet pipe to purified water distribution.
  5. Connect drain line to proper wastewater disposal.
  6. Plug into grounded electrical outlet.

WARNING! System operates under high pressure; ensure all connections are secure and leak-free before operation.

First-Time Setup

Power on system; follow initialization sequence.

  1. Prime the system: Open supply valve slowly to fill filters with water.
  2. Run initial flush: Allow system to run for 15 minutes to clear manufacturing residues.
  3. Configure settings: Use digital panel to set language, time, and purification mode.
  4. Connect to app: Download Jandy PureLink app and pair via Wi-Fi.
  5. Calibrate sensors: Follow on-screen prompts for water quality calibration.

CAUTION! Do not consume water during initial flush cycle. Wait for system to indicate "Ready" status.

Specifications

Controls and Settings

Access system controls via Digital Control Panel or mobile app.

Control Panel: POWER, MODE SELECT, FILTER STATUS, BACKWASH, SETTINGS, ALERT RESET.

Purification Modes: STANDARD (balanced purification), BOOST (maximum purification), ECO (energy saving). Water Quality Settings: TDS target level, pH balance, mineral content. Maintenance: Filter replacement reminders, backwash scheduling, system diagnostics. Smart Features: Usage tracking, water quality reports, remote control.

Connecting to Water Supply

Proper water connection ensures optimal performance and prevents damage.

  1. Ensure main water supply is turned off.
  2. Install pressure regulator if supply exceeds 100 PSI.
  3. Connect 3/4" inlet pipe to cold water line.
  4. Connect 1/2" outlet pipe to purified water distribution.
  5. Install drain line with air gap to prevent backflow.
  6. Check all connections for leaks before full operation.

Tip: Install sediment pre-filter if water source has high particulate content.

Operation and Maintenance

Daily operation is automatic; regular maintenance ensures peak performance.

  1. Normal Operation: System operates automatically when water is demanded.
  2. Filter Monitoring: Check digital display for filter status and replacement alerts.
  3. Backwash Cycle: Automatic every 2 weeks; manual initiation available.
  4. UV Lamp Replacement: Replace annually for optimal sterilization.
  5. Mineral Cartridge: Replace every 12 months or as indicated.
  6. System Flush: Perform quarterly to remove accumulated sediments.
  7. Sensor Calibration: Calibrate water quality sensors every 6 months.

WARNING! Always turn off power and water supply before performing maintenance.

Smart Features

Jandy PureLink Connect app provides advanced monitoring and control.

Remote Monitoring: Real-time water quality data, usage statistics, system status. Smart Alerts: Filter replacement notifications, maintenance reminders, error codes. Usage Reports: Daily/weekly/monthly water consumption and quality trends. Remote Control: Start/stop system, initiate backwash, change purification modes. Firmware Updates: Automatic system updates for improved performance.

Care & Cleaning

Regular cleaning maintains appearance and prevents performance issues.

  1. Exterior: Wipe with damp cloth; avoid abrasive cleaners.
  2. Control Panel: Clean with soft, dry cloth only.
  3. Drain Line: Flush monthly to prevent clogging.
  4. Pressure Gauges: Wipe clean; ensure clear visibility.
  5. Ventilation: Keep area around unit clear for proper airflow.

CAUTION! Never use harsh chemicals, solvents, or high-pressure water on the unit.

Regulatory Information

NSF/ANSI Standards: Complies with NSF/ANSI 42, 53, 58, and 401 for water treatment units. FCC Part 15: Class B digital device compliant. EPA Registered: UV sterilization system meets EPA requirements. Copyright © 2024 Jandy Water Systems; all rights reserved. For technical support, visit www.jandypurelink.com or contact 1-800-555-1234.

Troubleshooting

SymptomPossible CauseCorrective Action
No water flowWater supply off/clogged filterCheck water supply; inspect and replace clogged filters
Poor water qualityExpired filters/calibration neededReplace filters; recalibrate water quality sensors
System not powering onPower connection/breakerCheck power cord and outlet; reset circuit breaker
Error code displayedSystem fault/sensor issueRefer to error code chart in manual; contact support
Leaking connectionsLoose fittings/damaged sealsTighten connections; replace damaged O-rings and seals
Unusual noiseAir in system/pump issuePurge air from system; check pump operation

Reset: Hold POWER + SETTINGS for 10 seconds to factory reset.

Service: 1-800-555-1234; www.jandypurelink.com

Jandy PureLink Manual © - All Rights Reserved 2025