Jandy Stealth Pool Pump Manual

The Jandy Stealth Pool Pump is a high-efficiency, variable-speed pool pump designed for residential swimming pools. It features energy-saving operation, quiet performance, durable construction, digital controls, multiple speed settings, programmable timers, and compatibility with automation systems. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting to Pool Systems 7. Operation Modes 8. Maintenance & Cleaning 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Variable-speed motor, digital control panel, pump housing, strainer basket, see-through lid, power connection, and automation interface.

FeatureDescription
Variable-speed motorEnergy-efficient operation with multiple speed settings
Digital control panelEasy programming and status monitoring
Strainer basketLarge capacity for debris collection
See-through lidVisual inspection of basket and water flow
Power connectionStandard 115V/230V electrical connection
Automation interfaceCompatible with Jandy automation systems
Quiet operationReduced noise levels compared to standard pumps
Energy Star certifiedMeets energy efficiency standards
Programmable timerCustomizable run schedules
Freeze protectionAutomatic operation in freezing conditions

Installation

Unpack and inspect contents. Ensure proper location near pool equipment pad.

  1. Position pump: Place on level concrete pad near filter and other equipment.
  2. Plumbing connections: Connect suction and discharge pipes using appropriate fittings.
  3. Electrical connection: Connect to proper voltage (115V or 230V) with GFCI protection.
  4. Priming: Fill pump with water before initial start-up.

WARNING! Electrical shock hazard - disconnect power before servicing. Ensure all plumbing connections are secure and leak-free.

First-Time Setup

Power on pump; follow initial setup procedure.

  1. Prime pump: Open air relief valve, fill with water until water flows steadily.
  2. Set operating speed: Use control panel to select appropriate speed for your pool.
  3. Program timer: Set run times for optimal filtration and energy savings.
  4. Test operation: Verify proper water flow and check for leaks.

CAUTION! Never run pump dry - severe damage may occur. Ensure proper water level in pool.

Specifications

Controls and Settings

Access control panel via front display. Buttons: POWER, SPEED UP, SPEED DOWN, MENU, ENTER.

Display Indicators: Current speed, run time, timer status, error codes.

Speed Settings: 600-3450 RPM in 100 RPM increments. Timer Programming: Set daily schedules for different speeds. Menu Options: Language selection, freeze protection, priming mode, system reset. Automation: Compatible with Jandy Aqualink, iAqualink, and other control systems.

Connecting to Pool Systems

Suction side: Connect to skimmer and main drain. Discharge side: Connect to filter and return lines.

  1. Turn off power to all pool equipment before connecting.
  2. Use appropriate PVC fittings and sealant for watertight connections.
  3. Install unions for easy service and maintenance access.
  4. Connect automation cables if using control system integration.

Tip: Install check valve on discharge side to prevent backflow when pump is off.

Operation Modes

Supports multiple operating modes for different pool needs.

  1. Filtration Mode: Standard pool cleaning operation
  2. High-Speed Mode: For vacuuming, backwashing, or spa operation
  3. Low-Speed Mode: Energy-efficient continuous filtration
  4. Timer Mode: Programmed operation for specific times
  5. Freeze Protection: Automatic operation when temperatures drop below 34°F
  6. Priming Mode: Assists with initial pump startup

WARNING! Do not operate pump without proper water flow. Monitor pressure gauge for normal operating range.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Weekly: Check and clean strainer basket
  2. Monthly: Inspect pump lid O-ring and lubricate if necessary
  3. Seasonally: Check motor bearings and electrical connections
  4. Annually: Professional inspection of internal components

CAUTION! Always disconnect power before performing any maintenance. Use only manufacturer-approved replacement parts.

Regulatory Information

UL listed and CSA certified. Complies with NSF/ANSI 50 standards. Energy Star certified for energy efficiency. Copyright © 2024 Fluidra USA. Jandy is a registered trademark. For technical support, visit www.jandy.com or contact 1-800-227-1442.

Troubleshooting

SymptomPossible CauseCorrective Action
Pump won't startPower supply/breakerCheck power source; reset breaker; verify GFCI operation.
No water flowAir lock/primingPrime pump; check for suction leaks; verify water level.
Loud noise/vibrationDebris/worn bearingsClean strainer basket; check for obstructions; inspect motor.
High pressure readingClogged filterBackwash or clean filter; check for restricted flow.
Pump losing primeSuction leaksCheck lid O-ring; inspect pipe connections; verify valve positions.
Error codes displayedSystem faultsRefer to error code chart in manual; reset if necessary.

Reset: Press and hold POWER button for 10 seconds to reset control system.

Service: 1-800-227-1442; www.jandy.com

Jandy Stealth Pool Pump Manual © - All Rights Reserved 2025