Jandy Valve Actuator 2444 Manual

The Jandy Valve Actuator 2444 is an automatic pool valve actuator designed for controlling water flow in pool and spa systems. It features multi-position operation, manual override capability, LED status indicators, weather-resistant construction, and compatibility with various Jandy automation systems. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting to Automation Systems 7. Operation Modes 8. Maintenance 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Motorized actuator assembly, manual override lever, LED status lights, mounting hardware, and wiring connections.

FeatureDescription
Manual override leverAllows manual valve operation during power loss
LED status indicatorsShows power status and valve position
Weather-resistant housingDesigned for outdoor pool environments
Multi-position operationPool, Spa, and Spillover modes available
Power connectorFor connection to automation system
Mounting bracketSecure attachment to Jandy Never-Lube valves
Manual mode switchSwitches between automatic and manual operation
Position indicatorShows current valve position
Wiring terminalsFor connection to control systems
Actuator motor24V AC motor for reliable operation

Installation

Unpack and inspect contents. Ensure proper mounting surface.

  1. Mount actuator: Align with valve stem and secure with mounting bracket.
  2. Connect wiring: Route low-voltage wires to automation system.
  3. Power connection: Connect to 24V AC power source from automation panel.
  4. Test operation: Verify proper valve movement and positioning.

WARNING! Disconnect power before installation. Ensure proper valve alignment to prevent damage.

First-Time Setup

Power on actuator; configure automation system.

  1. Set valve positions: Program Pool, Spa, and Spillover positions in automation system.
  2. Configure timing: Set appropriate delay between position changes.
  3. Test all modes: Verify proper operation in all programmed positions.
  4. Set manual override: Ensure manual lever operates smoothly.

CAUTION! Do not force manual override. Ensure power is disconnected during manual operation.

Specifications

Controls and Settings

Access settings through connected automation system. Manual controls: Override lever, mode switch.

Automation Control: Pool mode, Spa mode, Spillover mode, custom positions via automation programming.

LED Indicators: Green light indicates power and normal operation. Red light indicates fault or obstruction. Manual Override: Pull up to engage manual mode, rotate lever to desired position. Position Settings: Configure through automation system interface for precise water flow control.

Connecting to Automation Systems

Compatible with Jandy Aqualink, iAqualink, and other Jandy automation systems.

  1. Turn off power to automation system before connecting.
  2. Connect actuator wires to valve actuator terminals on control board.
  3. Route wiring through conduit for protection.
  4. Program actuator in automation system setup menu.

Tip: Label all wires for easy identification during maintenance.

Operation Modes

Supports multiple water flow configurations.

  1. Pool Mode: Directs water flow to pool returns only.
  2. Spa Mode: Directs water flow to spa returns only.
  3. Spillover Mode: Creates water spillover from spa to pool.
  4. Manual Mode: Use override lever for manual control.
  5. Automated Sequences: Program through automation system for scheduled operation.

WARNING! Do not operate manual override while actuator is powered. Wait for complete stop before engaging manual mode.

Maintenance

Regular inspection and cleaning recommended.

  1. Monthly: Check for smooth operation and proper positioning.
  2. Quarterly: Inspect wiring connections and housing integrity.
  3. Annually: Verify mounting bracket security and valve alignment.
  4. As needed: Clean exterior with mild soap and water.

CAUTION! Do not use high-pressure water for cleaning. Ensure power is disconnected during maintenance.

Regulatory Information

UL listed and CSA certified. Complies with pool equipment safety standards. Copyright © 2024 Jandy; trademarks of Fluidra. For technical support, visit www.jandy.com or contact 1-800-822-7933.

Troubleshooting

SymptomPossible CauseCorrective Action
Actuator not movingPower loss/obstructionCheck power supply; verify automation system output; remove obstructions.
LED not illuminatedPower connectionCheck wiring connections; verify 24V AC power at terminals.
Incorrect positioningProgramming/alignmentReprogram automation system; check valve stem alignment.
Manual override stuckEngaged during powerDisengage manual override; ensure power is off before manual operation.
Noise during operationWorn componentsInspect gears and moving parts; lubricate if specified in manual.

Reset: Power cycle actuator and reprogram automation system if needed.

Service: 1-800-822-7933; www.jandy.com

Jandy Valve Actuator 2444 Manual © - All Rights Reserved 2025