The Janitrol HPT18 60 is a high-efficiency gas furnace with 60,000 BTU input capacity, featuring a hot surface ignition system, multi-speed blower motor, electronic thermostat compatibility, safety controls including flame rollout and limit switches, and durable heat exchanger construction. Designed for residential heating applications with AFUE ratings up to 80%. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Hot surface ignition system, multi-speed direct drive blower, aluminized steel heat exchanger, electronic thermostat control, safety switches, and diagnostic LED indicator.
| Feature | Description |
|---|---|
| Input Capacity | 60,000 BTU/hour |
| Ignition System | Hot surface ignition |
| Blower Motor | Multi-speed direct drive |
| Heat Exchanger | Aluminized steel construction |
| Thermostat Compatibility | Standard 24V electronic |
| Safety Controls | Flame rollout and limit switches |
| Diagnostic LED | Error code display |
| Gas Connection | 1/2" NPT |
| Electrical Requirements | 120V AC, 60Hz |
| Vent Requirements | Category I venting |
Proper installation is critical for safe and efficient operation. Follow all local codes and manufacturer guidelines.
WARNING! Installation must be performed by qualified HVAC technician. Gas leaks can cause explosion or fire.
Initial startup and system verification procedures.
CAUTION! Never bypass safety controls. Always verify proper venting before operation.
Main control board manages all furnace functions with integrated diagnostic capabilities.
Control Board: Monitors safety circuits, controls ignition sequence, manages blower operation, and displays error codes via LED indicator.
Operating Sequence: Thermostat call for heat → Inducer motor starts → Pressure switch verification → Hot surface ignition → Gas valve opens → Flame detection → Blower starts after heat exchanger warm-up.
Temperature Control: Adjustable blower off delay and heating anticipator settings available through DIP switches.
Standard 24V thermostat connections and 120V power requirements.
Tip: Use wire nuts and electrical tape for all connections. Follow local electrical codes.
Regular maintenance ensures optimal performance and longevity.
WARNING! Always turn off gas and electrical power before performing maintenance.
Multiple safety systems protect against hazardous conditions.
Flame Rollout Switch: Detects flame outside combustion chamber and shuts down system.
High Limit Switch: Prevents overheating by monitoring heat exchanger temperature.
Pressure Switch: Ensures proper inducer operation before gas valve opening.
Flame Sensor: Verifies burner ignition and shuts off gas if no flame detected.
Regular cleaning maintains efficiency and prevents premature failure.
Air Filter: Replace every 1-3 months depending on usage and environment.
Burners: Clean annually with soft brush and compressed air.
Blower: Vacuum accessible areas and clean blower wheel.
Heat Exchanger: Professional inspection and cleaning recommended.
CAUTION! Never operate furnace without air filter. Keep combustion area clear of debris.
UL listed and ANSI certified for safe operation. Complies with ASHRAE standards for residential gas furnaces. Manufactured to meet or exceed industry safety standards. For technical support or warranty information, contact Janitrol customer service at 1-800-555-HEAT or visit www.janitrol.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, safety lockout | Check circuit breaker, thermostat settings, reset safety switches |
| No heat | Gas supply, ignition failure | Verify gas valve on, check for ignition lockout, inspect flame sensor |
| Short cycling | Dirty filter, limit switch | Replace air filter, check for blocked vents, verify proper airflow |
| Blower not running | Motor, capacitor, control board | Check blower motor operation, test capacitor, verify control signals |
| Unusual noises | Blower, inducer, ductwork | Inspect blower wheel, check inducer motor, examine duct connections |
Reset Procedure: Turn thermostat off, wait 30 seconds, turn back on. If problem persists, check diagnostic LED for error codes.
Service: 1-800-555-HEAT; www.janitrol.com